Product Identification
Product ID:ECCOSHIELD VY-81
MSDS Date:10/21/1987
FSC:8030
NIIN:00N064960
MSDS Number: BZKWK
Responsible Party
WOBURN, MA 01888
US
Emergency Phone: 617-935-4850; 617-938-8630
Info Phone: 617-828-3300
Cage: DO244
Contractor
Telephone: (617) 935-4850 OR (617) 938-8630
Cage: DO244
Ingredients
7%.
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 20-25%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SILVER (SARA 313) (CERCLA)
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: <5%
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
POLYDIMETHYL SILOXANE; (NON-HAZARDOUS MINERAL FILLERS)
CAS: 9016-00-6
RTECS: TQ2690000
OSHA PEL N/K
ACGIH TLV: N/K
DRAINS, SEWERS & OTHER WATERWAYS. EXTING OPEN FLAMES
RTECS: 9999999ZZ
ELEC POWER TO AREA. SHOVEL/PUMP TO DRUM/SALVAGE TANK.
RTECS: 9999999ZZ
MATL. SCRAPE/SHOVEL ABSORBED WASTE & ABSORBENT INTO
RTECS: 9999999ZZ
FROM ENTERING DRAINS OR OTHER WATERWAYS.
RTECS: 9999999ZZ
PREVENT LOCAL BUILDUP OF VAPOR.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:VAPORS MAY CAUSE
IRRITATION TO RESPIRATORY TRACT & MAY EXERT NARCOTIC OR ANESTHETIC
EFFECTS. EYE:IRRITATION UPON DIRECT CONTACT. VAPORS MAY BE
IRRITATING. SKIN:IRRITATION UPON DIRECT CONTACT. INGESTION:HARMFUL
IF SWALLOWED. CHRONIC:PROLONGED CONTACT W/SILVER COMPOUNDS MAY LEAD
TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ABSORPTION & DISCOLORATION OF SKIN.
Medical Cond Aggravated by Exposure:NO DATA AVAILABLE FOR THIS PRODUCT
MIXTURE.
First Aid
First Aid:GET MED ATTN IF SYMPS PERSIST. INHAL:REMOVE TO FRESH AIR.
GIVE ARTF RESP IF NOT BRTHG. GIVE OXYG IF BRTHG DFCLT. GET IMMED
MED ATTN. EYE:IMMED FLUSH W/WATER FOR AT LST 15 MINS; GET MED ATTN.
SKIN:REMO VE CONTAM CLTHG, WASH AFFECTED AREA W/WATER.
INGEST:DILUTE W/LG QTYS OF WATER; INDUCE VOMIT ONLY IF VICTIM IS
CONSCIOUS & ALERT. GET IMMED MED ATTN.
Fire Fighting
Flash Point Method:TCC
Flash Point:81.0F,27.2C
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL CNTNRS W/WATER IF LG QTYS OF MATL ARE INVOLVED,
EVACUATE AREA & FIGHT FIRE FROM SAFE DIST.
Unusual Fire/Explosion Hazard:TOXIC VAPORS MAY BE EVOLVED UPON EXPOSURE
TO HEAT OR OPEN FLAME. WARNING:FLAMMABLE MATL - KEEP AWAY FROM
HEAT, SPARKS OR OPEN FLAME.
Accidental Release
Spill Release Procedures:NOTE:USE ONLY SPILL RESPONSE EQUIP APPRVD FOR
POTNTL FLAMM/EXPLO ENVIRONS. NIOSH/MSHA APPRVD RESPS SHOULD BE WORN
DURING CLEAN-UP OF LG SPILLS. FOR SM SPILLS:TURN ON VENT EQUIP TO
EVACUATE VAPS FROM A REA. EXTING OPEN FLAMES & ELIM ALL OTHER
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CAUTION:TREAT AS FLAMM MATL. KEEP AWAY
FROM HEAT, SPKS & OPEN FLAME. AVOID BRTHG VAPS. USE ONLY W/ADEQ
VENT. AVOID SKIN & EYE CONT.
Other Precautions:STORE IN COOL, DRY PLACE; KEEP REMOVED FROM ANY HEAT
OR OPEN FLAME. AVOID STATIC ELECTRICITY - LARGE CONTAINERS MUST BE
KEPT GROUNDED AT ALL TIMES.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS SHOULD BE USED IN THE ABSENCE OF MECHANICAL VENTILATION
WHEN WORKING W/LARGE QUANTITIES OF MATERIAL.
Ventilation:EXPLO-PROOF VENT EQUIP SHOULD BE USED FOR LOC VENT.
FLEXIBLE DUCTWORK SHOULD EXTEND TO AREAS OF HIGH CONC TO (ING 8)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR PROTECTIVE CLOTHING TO PREVENT
EXPOSURE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT:<25(WT). SPILL PROC:SOURCES OF IGNIT IN AREA. WIPE UP/ABSORB
W/VERMICULITE OR OTHER ABSORB MATL. SCRUB AREA W/SOAPY WATER &
RINSE. PREVENT RINSES FROM ENTERING DRAINS/OTHER WATERWAYS. FOR LG
S PILLS:TURN ON VENT EQUIP TO EVACUATE VAPS FROM AREA. DIKE AREA TO
CONTAIN SPILLED MATL & TO PVNT RUNOFF INTO (ING 4)
Chemical Properties
Vapor Pres:2 @ 25C
Vapor Density:HVR/AIR
Spec Gravity:1.5 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVER PASTE.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS.
Stability Condition to Avoid:STORAGE IN OPEN CNTNRS, EXPOS TO HEAT &/OR
OPEN FLAME, UNCONTROLLED MIXING WITH (OR EXPOSURE TO) INCOMPAT
SUBSTANCES.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SILICON DIOXIDE, HYDROCARBONS.
Disposal
Waste Disposal Methods:DISPOSE OF AS A HAZARDOUS MATERIAL I/A/W CURRENT
LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.